InCloud Rail IR5280M7ÊǺÀÔ˹ú¼ÊÍƳöµÄÒ»¿îÅÌËã´æ´¢Æ½ºâÐͳ¬ÈÚºÏÒ»Ìå»ú£¬¾ßÓиßÀ©Õ¹ÐÔ¡¢ÎÞаѡÅäµÈÌØÕ÷£¬¿ÉÒÔ×ÊÖúÓû§¿ìËÙ¹¹½¨ÔÆÊý¾ÝÖÐÐÄ£¬½µµÍTCOºÍÖØ´óÐÔ£¬²¢ÇÒÄܹ»ÎÞа¡¢¿ìËÙ½»¸¶¡£
¡¡¡¡ºÀÔ˹ú¼ÊÔƺ£³¬ÈÚºÏÒ»Ìå»úInCloud Rail IR5280M7ÊÇÒ»¿îÅÌËã´æ´¢Æ½ºâÐ͵ÄÔÆÅÌËã»ù´¡ÉèÊ©·þÎñƽ̨£¬¿ÉÖª×ãÆóÒµ¼¶Ó¦Óü°Êý¾ÝÖÐÐÄ¡¢±ßÑØÅÌËãµÈ¶àÑù»¯È«³¡¾°ÐèÇ󡣸Ãƽ̨¾ßÓÐÈ¥ñîºÏ¡¢¿ÉÖع¹¡¢×Ô¶¯»¯¡¢ÕûÌåÐÔ¡¢µ¯ÐÔ»¯µÈÌص㣬¿ÉÒÔ×ÊÖúÓû§¿ìËÙ¹¹½¨ÔÆÊý¾ÝÖÐÐÄ£¬½µµÍ TCOºÍÖØ´óÐÔ£¬²¢ÇÒÄܹ»ÎÞаÀ©Õ¹¡¢¿ìËÙ½»¸¶¡£
ͬԴÒì¹¹£¬ÈÚºÏÖÁ¼ò
ƽ̨ÌṩÐéÄâ»ú¡¢ÈÝÆ÷¡¢Âã½ðÊôµÈ¶àÔªËãÁ¦£¬Öª×ã²î±ðÓ¦Óó¡¾°ÐèÇó£»Ö§³ÖÅÌËã¡¢´æ´¢¡¢ÍøÂç¡¢¼à¿ØËß¾¯¡¢µ¯ÐÔ¸ÄÅäÀ©ÈݵÈALL IN ONE½çÃæ¹ÜÀí£¬ÅäºÏÇáÁ¿»¯ÔƹÜÀíƽ̨¿ÉÌṩ¶à¼Ü¹¹/¶àÕ¾µãͳһ¹ÜÀíÄÜÁ¦£¬±ã½ÝʽÔËάÔËÓªÖúÁ¦½µ±¾ÔöЧ¡£
È«Õ»RDMA£¬ÐÔÄÜÌØÊâ
Ö§³ÖÐÂÒ»´úÓ¢Ìضû®ÖÁÇ¿®¿ÉÀ©Õ¹´¦Öóͷ£Æ÷¡¢4800MT/s DDR5 ECCÄڴ棬¿ÉÌṩǿ¾¢ÅÌËãÐÔÄÜ£»ÈíÓ²ÐͬÉî¶ÈÓÅ»¯£¬ÄÚÖÃÂþÑÜʽ´æ´¢¼ÓËÙ¡¢ÖÇÄÜÍøÂç¼ÓËÙµÈÒªº¦ÊÖÒÕ¡£½ÓÄɼÓËÙÒýÇ桢ȫջRDMAµÄÊý¾Ý´«ÊäͨµÀ£¬Ìṩ׿ԽµÄÍøÂç¼°´æ´¢ÐÔÄÜ¡£
¶àÖر£»¤£¬¼«Ö¿ɿ¿
ƽ̨֧³Ö¸ß¿ÉÓá¢Ë²Ê±¿ìÕÕ¡¢ÐéÄâ¼Ӱ»ú¡¢CBT±¸·Ý¡¢Ë«»î´æ´¢³ØµÈÈí¼þ¹¦Ð§ºÍSRMÒìµØÈÝÔÖµÈÊý¾ÝÖÐÐļ¶ÈÝÔּƻ®Î¬»¤ÓªÒµÒ»Á¬ÐÔÓëÊý¾ÝÇå¾²£¬ÍŽáÊýǧÌõÈíÓ²¼þ¼æÈÝÐÔ²âÊÔÓ붨ÖÆÓ²¼þµ÷ÓÅ£¬ÓÐÓÃÆÁÕÏÈíÓ²¼þ¹ÊÕÏ´øÀ´µÄÓªÒµÖÐÖ¹£¬×îºéÁ÷ƽ°ü¹Üƽ̨¿É¿¿ÐÔ¡£
¿ª·Å±ê×¼£¬Éú̬¹²Ïí
¿ª·Å±ê×¼»¯Rest APIJava SDK£¬¼æÈÝ÷è÷롢ͳÐÅ¡¢·½µÂ¡¢ÆÕ»ª¡¢Äý˼µÈÖ÷Á÷OS£¬ÄÏ´óͨÓá¢ÈË´ó½ð²Ö¡¢å«¸ß¡¢Öд´µÈÖ÷Á÷Êý¾Ý¿âÓëÖÐÐļþ£»¿ª·ÅÔÆÖ÷»úÓë¶àÖÖÍøÔªÓ¦ÓÃÎÞËð¿É¿Ø¶Ô½Ó£¬Ìṩ¿ª·ÅµÄ±ê×¼ÔÖ±¸½Ó¿ÚVVDK£¬ÎªÓû§¹¹½¨Ç¿Ê¢µÄ²úÆ·Éú̬ϵͳ¡£
¡¡ |
×é¼þ |
ÐÎò |
³¬ÈÚºÏ×°±¸ |
¹æ¸ñ |
2U»ú¼Üʽ³¬Èںϣ¬ÊÊÓÃÓÚͨÓûú·¿ÇéÐΣ¬Ö§³Ö±ê×¼»ú¹ñ |
´¦Öóͷ£Æ÷ |
Ö§³Ö1¿Å»ò2¿ÅÓ¢Ìضû® ÖÁÇ¿®µÚËÄ´ú¿ÉÀ©Õ¹´¦Öóͷ£Æ÷ ×î¶àÖ§³Ö60ºË£»×î¸ßî£Æµ4.2GHz |
|
ÄÚ´æ |
×î¶àÖ§³Ö32ÌõDDR5 4800MT/sÄÚ´æ µ¥¿ÅCPUÖ§³Ö16ÌõDIMM¡¢Á½¿ÅCPUÖ§³Ö32ÌõDIMM Ö§³ÖRDIMMÀàÐÍ |
|
´æ´¢ |
Ç°ÖÃÃæ°å¿ÉÖ§³Ö£º12*3.5¡±SAS/SATA/NVMeÓ²ÅÌ£¬»òÕß24*2.5¡±SAS/SATA/NVMeÓ²ÅÌ£¬»òÕß25*2.5¡±SAS/SATAÓ²ÅÌ(×î´óÖ§³Ö4*NVMe)£¬ »òÕß24*E3.S SSD |
|
ºóÖÃÃæ°å¿ÉÖ§³Ö£º4*3.5¡±SAS/SATAÓ²Å̼°4*2.5¡±SAS/SATA/NVMeÓ²ÅÌ£¬»òÕß4*3.5¡±SAS/SATAÓ²Å̼°2*SATA M.2/E1.S SSD |
||
ÄÚÖô洢£º ×î´óÖ§³Ö2*SATA M.2»ò2*PCIe x4 M.2 |
||
ÕóÁп¨ |
RAID¿¨¿ØÖÆÆ÷¡¢SAS¿¨¿ØÖÆÆ÷ °åÔØPCHÖ§³Ö14*SATA½Ó¿Ú Intel°åÔØNVMe¿ØÖÆÆ÷£¬¿ÉÑ¡ÅäIntel NVMe Raid Key |
|
Íø¿¨ |
ÍƼöÉèÖãº1G¹ÜÀíÍø½Ó¿Ú¡Ý2¸ö£¬25G´æ´¢Íø½Ó¿Ú¡Ý2¸ö£¨º¬¶àÄ£¹âÄ£¿é£©£¬25GÓªÒµÍø½Ó¿Ú¡Ý2¸ö£¨º¬¶àÄ£¹âÄ£¿é£© |
|
µçÔ´¼°ÍâÉè |
Ö§³Ö1+1ÈßÓà800W/1300W/1600W/2000W/2700W CRPS±ê×¼µçÔ´£» 6¸öÈȲå°ÎN+1ÈßÓà˫ת×ÓµçÉÈ |
|
ϵͳ¹ÜÀí |
¼¯³É1¸ö×ÔÁ¦µÄ1000MbpsÍøÂç½Ó¿Ú£¬×¨ÃÅÓÃÓÚIPMIµÄÔ¶³Ì¹ÜÀí |
|
Ö÷»ú³ß´ç |
º¬¹Ò¶ú£ºW£¨¿í£©482.4mm£»H£¨¸ß£©87mm£»D£¨É828.4mm ²»º¬¹Ò¶ú£ºW£¨¿í£©435mm£»H£¨¸ß£©87mm£»D£¨É800mm |
|
³¬ÈÚºÏϵͳ |
ÅÌËãÐéÄ⻯ |
½ÓÄÉ×ÔÖ÷Ñз¢¡¢»ùÓÚ KVM Éî¶È¶¨ÖƵÄÅÌËãÐéÄ⻯Èí¼þ InCloud Sphere£¬Ö§³Ö×ÊÔ´Ô¤Áô¡¢ÈÈÌí¼Ó¡¢GPU ֱͨ¡¢vGPU¡¢USB Over IP¡¢ DRS¡¢DRX¡¢Âã»ú¹ÜÀí¡¢ÐéÄâ¼Ӱ»ú¡¢´ÅÅÌË«»îµÈ¶àÖָ߼¶ÌØÕ÷ |
´æ´¢ÐéÄ⻯ |
½ÓÄɺÀÔ˹ú¼Ê×ÔÖ÷Ñз¢µÄÆóÒµ¼¶ÂþÑÜʽ´æ´¢ÏµÍ³ InCloud dSAN£¬Ö§³ÖÀäÈÈÊý¾Ý×Ô¶¯Ê¶±ð¡¢I/O Êý¾ÝÍâµØ»¯¡¢Êý¾Ý¿éУÑé¡¢»ú¼Ü¸ÐÖª¡¢Êý¾Ý×Ô¶¯Æ½ºâ»Ö¸´¡¢´ÅÅÌÖÜÓΡ¢È«¾ÖRDMAµÈ¸ß¼¶ÌØÕ÷¡£ |
|
ÍøÂçÐéÄ⻯ |
½ÓÄɺÀÔ˹ú¼Ê×ÔÖ÷Ñз¢µÄÂþÑÜʽ SDN Èí¼þ InCloud SmartFlow£¬Ö§³ÖÍøÂç×ÓÍø»®·Ö¡¢¸ôÀë¡¢sFlow¡¢¶Ë¿Ú¾µÏñ¡¢DHCP·À»¤µÈ¹¦Ð§¡£´îÅäÖÇÄÜÍø¿¨£¬ÊµÏÖ SDN ¿ØÖÆÆ÷Ö÷»úжÔØ£¬½ÚÔ¼CPU ×ÊÔ´µÄͬʱ£¬´ó·ù¶ÈÌá¸ßת·¢ËÙÂÊ¡£ |